CMX EVAC-240RT (EN54-16 PAVA System Router 6 Zone)

รหัสสินค้า : EVAC-240RT

ราคา

฿ 0.00

จำนวนที่จะซื้อ
ราคารวม ฿ 0.00

สินค้าไม่เพียงพอ

สินค้าหมด

CMX EVAC-240RT (EN54-16 PAVA System Router 6 Zone)


Overview

6 Zone Router, built-in 240W class-D amplifier, with 6 zone speaker outputs and volume control, receive

sources and fire alarm message from master controller, with AB speaker line low impedance

supervision, with amplifier auto changeover into standby when fault, with extension amplifier connector,

AC and DC battery operation.                                                         


Features:

  • The EN54-16 certificated PAVA system router is needed for more than 6 zone voice alarm system.
  • Built-in 240W 6 zone class-D amplifier.
  • With same function with EVAC-240 voice alarm controller except control function.
  • The expansion router will be controlled by master voice alarm controller.
  • Integration of EVAC controller, paging system, PA system & BGM system together.
  • Built-in two separate players for EVAC and alert voice message by SD card.
  • Built-in 6 zone AB speaker line low impedance supervision.
  • Built-in amplifier auto changeover into standby when fault.
  • With external amplifier input to expansion the power.
  • Capacity of connection 32 remote microphones.
  • 6 zone speaker outputs with separate zone volume control (ATT).
  • 6 zone separate indicator for EVAC, fault, music/paging & select.
  • System indicators of AC, DC, fault and indicators for EVAC & alert.
  • Zone capacity of 120 zones by cascaded 19 routers.
  • With 8 programmable control inputs and 8 programmable control outputs for voice evacuation system.
  • With Fault, EVAC outputs and Reset input for third party system integration.
  • Priority level: fireman microphone, EVAC, input 1, remote microphone, timer & BGM.
  • Two combo inputs for microphone/line, 4 line inputs and one REC output.
  • Two RJ45 ports for router, two RJ45 for remote microphone input and two RJ45 for LAN/WAN/Internet network.
  • IP network module for optional to buy.
  • AC 230V and DC24V battery input. Auto switch into the battery backup when AC fails.

Specifications

Model
EVAC-240RT
Description
EN54-16 PAVA System Router 240
Rated Power Output
240W
Fireman Microphone
5mv, 600Ω
Line 1-2 Inputs
385mV, 10kΩ, balanced Combo
Line 3-6 Inputs
350mV, 10kΩ, RCA
Frequency Response
80Hz~20kHz
THD
<1% at RMS,1KHz
S/N Ratio
>70dB
Speaker Output
100V AB 8 zone speaker outputs
REC Output
200mV
Control Input & Output
8 programmable control inputs: Max 3.3V (voltage mode) or 0V closed contact
8 programmable control outputs: 0V closed contact; Control output for fault & EVAC: 0V closed
contact; Reset control input: 0V closed contact
Voice Message
MP3 or WMA format, two separate players of SD card with protection cover, programmable voice message up to 255, 10 years valid
Event Record
HEX format, Hard Flash memory, events up to 1000 records, 10 years valid
Operation Environment
Operation Temp: +5℃ ~ +40℃; Store Temp: -20℃ ~ +70℃; Humidity:<95%
Power Consumption
300W
Power Supply
AC230V or 115V & DC24V battery inputs, 50-60HZ
AC Fuse
250V/6.3A, slow type and restorable fuse
Dimension
484(W)×132(H)×449(D) mm
Weight
21kg
Visitors: 62,683